Spindle Wiring Connections
1.5KW Connection
Wire | Core | Connection | Description |
---|---|---|---|
VFD | 1 | Spindle U | U Phase |
VFD | 2 | Spindle V | V Phase |
VFD | 3 | Spindle W | W Phase |
VFD | 4 | Spindle Earth | Earth Connection |
VFD | Screen | Spindle Earth | Sleeve and connect into the same earthing point as VFD4 |
2.2KW Connection
Wire | Core | Connection | Description |
---|---|---|---|
VFD | 1 | Spindle U | U Phase |
VFD | 2 | Spindle V | V Phase |
VFD | 3 | Spindle W | W Phase |
VFD | 4 | Spindle Earth | Earth Connection |
VFD | Screen | Spindle Earth | Sleeve and connect into the same earthing point as VFD4 |
6KW ISO30 ATC Connections
Wire | Core | Connection | Description |
---|---|---|---|
VFD | 1 | Spindle U | U Phase |
VFD | 2 | Spindle V | V Phase |
VFD | 3 | Spindle W | W Phase |
VFD | 4 | Spindle Earth | Earth Connection |
VFD | Screen | Spindle Earth | Sleeve and connect into the same earthing point as VFD4 |
ATC 1 | 1 | Pin 1 | Output Signal for Sensor S2 (Ejection) |
ATC 1 | 2 | Pin 2 | Output Signal for Sensor S1 (Locking) |
ATC 1 | 3 | Pin 3 | Spare, optional Thermistor connection. |
ATC 1 | 4 | Pin 4 | +24VDC supply for S1, S2, Manual Switch Light |
ATC 2 | 1 | Pin 5 | 0VDC (GND) for S1, S2, Switch Light |
ATC 2 | 2 | Pin 6 | Output Signal for Manual Switch |
ATC 2 | 3 | Pin 7 | +24VDC supply for Cooling Fan |
ATC 2 | 4 | Pin 8 | 0VDC (GND) for Cooling Fan. This is the switch wire |