Tool Setter Probe Calibration
Tool Offset Probe Calibration
For a brand new machine you will need to calibrate the tool probe.
Before calibrating the G59.9 (tool probe) WCS, you should install a tool into the spindle, sticking out roughly 35mm.
Move the spindle directly above the tool probe, before running the following g-code. (ATC machines will need to turn off soft limits)
G49 //clear offset
G59.9 //selecting tool probe WCS P60
G37 //run probe
G10 L20 P60 X0 Y0 // set coordinates
M500 //save
G54.0 / change back into another WCS
IMPORTANT!! Run a tool change after calibration to make sure the correct tool height is set, as the calibration steps do not do this!
Video here on how it functions once its calibrated. Get a 6mm drill bit or one of your new tools, measure it with some calipers as you will need it for the calibration.